Radwag E2R Weighing Records Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Radwag E2R Weighing Records. RADWAG E2R Weighing Records User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation manual
E2R SYSTEM Program
Manual number:
ITKI-15-02-03-14-PL
MANUFACTURER OF ELECTRONIC WEIGHING EQUIPMENT
RADWAG, 26 – 600 Radom, 28 Bracka Street
POLAND
phone +48 48 38 48 800, phone/fax. +48 48 385 00 10
Sales Department +48 48 366 80 06
www.radwag.pl
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - Installation manual

Installation manual E2R SYSTEM Program Manual number: ITKI-15-02-03-14-PL MANUFACTURER OF ELECTRONIC WEIGHING EQUIPMENT

Strany 2 - Contents

CLIENT / ONLY E2R SYSTEM -The Software installation version with the on-line monitoring, intended for installation on additional computers in the net

Strany 3 - 1. SOFTWARE INSTALLATION

Menu Start folder selection box: Press ‘NEXT’ button. Additional tasks box during installation: Select additional tasks to do during the modu

Strany 4

Box ready for installation: Press ‘INSTALL’ to start the installation process. Program installation finish box: When the installation is com

Strany 5

During the software installation the following elements are also installed: • E2R_System (SQL base) database, • E2R Synchronizer, • E2R Manager, •

Strany 6

2. PROGRAM CONFIGURATION Another operation inevitable for the proper operation of E2R SYSTEM is, among others, the scale configuration in the system

Strany 7

The main program box: In the top bar of the application there is information about the program versions included in RADWAG Synchronizer. Th

Strany 8

Uninstall service Uninstalling RADWAG Synchronizer service from the MS Windows system. Run server RADWAG Synchronizer service server activation S

Strany 9

• On the server activation, you will see the Stop Server button, which means it was successfully activated. 2.1.1.2. Restart E2R Synchronizer

Strany 10

2.1.1.3. Uninstalling E2R Synchronizer service. • Press Stop Server button. • Press Uninstall service button. • On the uninstalling service

Strany 11

Connect with the database to configure the scales, press Connect button. Parametres bookmark: Server Access path to SQL server. Local server by d

Strany 12

Contents 1. SOFTWARE INSTALLATION ...3 1.1. Database...

Strany 13

File Scale messages language selection. TCP Port TCP port used by E2R Manager. By default: 4004. Login The E2R Manager program user name. By default

Strany 14 - 2. PROGRAM CONFIGURATION

2.1.3. Adding new scales In order to configure the scales, connect with the database pressing Connect button. After connecting with the database,

Strany 15

On pressing the button the scale edition box which should be filled in following the below screenshot. Adding a new scale is shown on the example of

Strany 16

Type Type of connection with the scale: • Radwag.Devices.PUE7.PUE7Encoder – Connection of industrial scales WLY, WPY and HTY series with the standar

Strany 17

Using Edit button, activate the box in which you can set up the communication interface parametres with the scale. The interface settings: Conne

Strany 18

Caution: All the above settings should be checked with the scale settings and communication port from MS Windows System. If during a scale adding (o

Strany 19

On pressing Remove you will see a request: The repeated request minimizes the risk of accidental removing the scale from the Synchronizer. On pres

Strany 20

pue41Towary_id2kod 0 Setting value 1 will send to PUE_C41 scale ID from the database as the scale code; • The name of product on the scale = the nam

Strany 21

Synch_LososTara 0 Setting the parametre on value 1 will turn on the function of product tare restoring from the database after the WPW scale clearing

Strany 22

Control lamp 0 Setting the parametre on value 1 will set up PUE4-L scale working mode as a controlling scale progi_z_reki 0 Setting the parametre o

Strany 23

1. SOFTWARE INSTALLATION 1.1. Database The installed database motor is MS SQL Express 2008 R2. E2R SYSTEM database on a new computer is always cr

Strany 24

All messages are only informative, which makes it impossible to save or print them out. This user manual features only the button options regardin

Strany 25

2.2.1. Settings of connection with E2R SYNCHRONIZER Box of settings activated from option File, Software Settings. In the box set up the addres

Strany 26

If E2R SYNCHRONIZER is installed on the same computer as E2R MANAGER, do not change the default IP address 127.0.0.1. Change the default port of ser

Strany 27

2.2.2. Scales configuration 2.2.2.1. Scales Configuration of scales is carried out on selecting option Scale in the menu Scales configuration.

Strany 28 - The scale button parametres:

2.2.2.1.1 Adding the scale In the configuration box press the button , next in the box below fill in all required blanks. Scale name A scale na

Strany 29

Order address Address set up on the scale, by default 1. Scale symbol The scale symbol on the scale overlay, required among others in the CPG system

Strany 30

Save the changes pressing button, or exit the box without saving the changes pressing button. 2.2.2.1.3 Scale removing In the configuratio

Strany 31

Turning the option on and off using the buttons: Option on, Option off. • Public Public options are available by default and their setup does

Strany 32

Enable updating from scale Activating the update of tare, thresholds, mass from the selected scale to the system, Enable tare updating from scale

Strany 33

Version No ... No of database version read from the scale, on the basis of this number bases on the scale are synchronized, Scale serial no Serial n

Strany 34

NOTE! Max number of records depends also on other tables size in a database, therefore, the real records number might vary from the determined number

Strany 35 - button

2.2.2.2. Global options System configuration can be carried out on selecting Global options in menu Scales configuration. In the box Server glob

Strany 36

Option on, Option off. • Public Public options are available by default and their setup does not influence the system work. . Carry out co

Strany 37

Enable updating from scale Option that enables the update of tare, limits, mass from the scale to the system Enable tare updating from scale Option

Strany 38

CAUTION! On WPW scale the field limitation does not allow to create codes longer than 6 characters. • Developer Developer (program) options are a

Strany 39

2.2.3.1. Restart local synchronizer Option available on computer on which E2R SYNCHRONIZER is activated. It enables to reload the server configurat

Strany 40

Time of displaying messages can be set up from 3 to 3600 seconds. To send the message press button, Or close the box pressing button.

Strany 41

When the system is in operation you can restart the scale by double-click on a selected scale symbol in E2R Manager. After several seconds the scale

Strany 42

Select the module from the list and press Set the Selected Module. If you have a licence it is recommended in the beginning to activate the

Strany 43

3.1.3. Module activation Every module activation is done only once and until the program another activation it will not be repeated. In case of a mu

Strany 44

The licence will be displayed in box Enter Key. Select the proper module and press Assign a key to the Module button. 49

Strany 45

NOTE! 1. It is not recommended to install other programs on the computer. 2. If the program is to be installed on the computer which is not supplie

Strany 46 - 3. E2R SYSTEM

If you assign an improper module to your key, the following message will be displayed. The successfully completed activation process will generate

Strany 47

3.2. Program settings Activate the settings pressing button in the top bar. 3.2.1. Database In order to activate database settings, click

Strany 48

3.2.1.1. Configure connection On pressing in the databases settings box, you will see database settings connection with the database. It featu

Strany 49

On closing the database settings, you will see the information about the program restart, which should be confirmed by pressing OK. 3.2.1.1.

Strany 50

Next the following message will be displayed. 3.2.1.1.2 Restore the latest copy of the database. Restoring the full SQL database can be done o

Strany 51 - button to stop

Depending on the database size, the operation takes several seconds, and the successful completion is confirmed with the below message. CAUTION

Strany 52

MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG Balances & Scales 26 – 600 Radom Bracka 28 POLAND phone. +48 48 38 48 800 f

Strany 53

The manual features the installation version „E2R SYSTEM 13.08.28”. After the file installation you will see a dialog box which enables the insta

Strany 54

Installation welcome box: In order to go on, press button ‘NEXT’. Licence agreement box: Accept the agreement conditions and press ‘NEXT’ butt

Strany 55

The operation system requirements information box: Press ‘NEXT’ button. Installation path selection box 8

Strany 56 - MANUFACTURER

Select the program localization in the box (do not change the path), then press button ‘NEXT’. NOTE: The system partition, usually disc-C needs to ha

Komentáře k této Příručce

Žádné komentáře